Line 21: Line 21:
         * 'ERROR ch -317 Total power integrator overflow on IF2'         * 'ERROR ch -317 Total power integrator overflow on IF2'
         * 'ERROR ch -350 The Receiver 20K stage is hotter than  40K'         * 'ERROR ch -350 The Receiver 20K stage is hotter than  40K'
 +        * caltsys disabled at 0145 as this was causing significantly shortened scans (missing approximately 6s of each scan). Disk pos lagging by 60 GB due to late start and this problem. ​ (JMc)
  
 **Katherine** **Katherine**
Line 28: Line 29:
     * 1753 UT - Experiment started late, but seems to be running ok. (Nick)     * 1753 UT - Experiment started late, but seems to be running ok. (Nick)
     * '​mk5=mode?'​ gives '0 : ext : 0xffffffff : 1 : 2 ; ' which is not in the wiki. (Nick)     * '​mk5=mode?'​ gives '0 : ext : 0xffffffff : 1 : 2 ; ' which is not in the wiki. (Nick)
 +    * 1414 UT PCFS died. Calling Warren (on call) to assist (Bryn) ​
 +    * 1552 UT PCFS still won't boot. (Bryn)
 +    * 1700 UT stowed telescope, still having issues with pcfs. Redoing setup to prepare for next experiment (Bryn)
 +
 +
  