User Tools

Site Tools


handover:aua032

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
handover:aua032 [2017/11/24 20:23]
Noor Md Said
handover:aua032 [2017/11/25 08:03] (current)
Ross Turner
Line 8: Line 8:
  
   * experiment started late due to schedule file. Missed the first scan no0001 (mas)   * experiment started late due to schedule file. Missed the first scan no0001 (mas)
 +  * 03:40 UT - Lost connection to telescope, seems to be a lightening strike which has knocked out multiple systems. The antenna stowed due to a high wind speed reading and cannot talk to the mark 5 or receiver. Hobart has left the experiment as of 08:00 UT (Ross)
  
 **Katherine 12m** **Katherine 12m**
Line 15: Line 16:
 Data volume at beginning: 1567.368 GB Data volume at beginning: 1567.368 GB
  
-  * experiment started late due to schedule file. Missed scan no0001,​no0002,​no0003,​no0004,​no0005,​no0006,​ no0007,​no0008 (mas+  * experiment started late due to schedule file. Missed scan no0001,​no0002,​no0003,​no0004,​no0005,​no0006,​ no0007,​no0008 (mas)
   * received quite regular warnings: error an -103 pointing computer tracking error are too large (mas)   * received quite regular warnings: error an -103 pointing computer tracking error are too large (mas)
   * ALARM: error m5 -900 not while recording or playing following with warning:​error m5 -906 mark5 return code inconsistent or conflicting request, occurred at UT 16:00:34, 16:36:02, 17:09:31 & 17:49:48 (mas)   * ALARM: error m5 -900 not while recording or playing following with warning:​error m5 -906 mark5 return code inconsistent or conflicting request, occurred at UT 16:00:34, 16:36:02, 17:09:31 & 17:49:48 (mas)
Line 27: Line 28:
   * experiment started OK (mas)   * experiment started OK (mas)
   * received quite regular warnings: error an -103 pointing computer tracking error are too large (mas)   * received quite regular warnings: error an -103 pointing computer tracking error are too large (mas)
 +  * 06:23 UT - The connection to the mark5 has been lost. Rebooted the mark 5 but cannot reconnect. Reconfigured the dbbc and rebooted the mark5 again. Resumed observing at 07:13 UT. Missed scans no0188 through no0196 (Ross)
  
  
  
/home/www/auscope/opswiki/data/attic/handover/aua032.1511554980.txt.gz · Last modified: 2017/11/24 20:23 by Noor Md Said