handover:aua047 [2018/12/05 10:59]
Tiege McCarthy
handover:aua047 [2018/12/05 15:42] (current)
Tiege McCarthy
Line 9: Line 9:
            * Fixed problem by resetting the drive pc (vdesk would not load sys26m which was a large diagnostic) with command: rem_reboot -r rakbus sys26m. For good measure, also opened vdesk with sys26m and abort, abort-ed. Then reset field system and voila, it worked. note - found this fix on the ra-wiki (not auscope wiki).            * Fixed problem by resetting the drive pc (vdesk would not load sys26m which was a large diagnostic) with command: rem_reboot -r rakbus sys26m. For good measure, also opened vdesk with sys26m and abort, abort-ed. Then reset field system and voila, it worked. note - found this fix on the ra-wiki (not auscope wiki).
            * First scan is 3338-1857, all previous scans missed.            * First scan is 3338-1857, all previous scans missed.
 +   * sx receiver parameter pres out of range showed up multiple times from 1414UT. However the values on the live page seem to be fine (Prad).
  
 **Katherine 12m** **Katherine 12m**