This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
handover:mv004 [2017/01/14 00:42] Lucas Hyland |
handover:mv004 [2017/01/14 11:45] Lucas Hyland |
||
---|---|---|---|
Line 13: | Line 13: | ||
Module HOB+0130, recorded 1043.582 GBs previously. | Module HOB+0130, recorded 1043.582 GBs previously. | ||
+ | |||
+ | * Power outage, antenna got stuck after the system recovered: | ||
+ | * halt | ||
+ | * disk_record=off | ||
+ | * antenna=off | ||
+ | * terminate | ||
+ | * in timeke, HMI, 'reset drives', wait until both comms stati are green | ||
+ | * fs | ||
+ | * proc=mv004ke | ||
+ | * setup01 | ||
+ | * antenna=open | ||
+ | * antenna=operate | ||
+ | * source=stow | ||
+ | And it moved. Then I restarted the schedule. Generator status was 'in auto-off' so I assumed the power came on without any problems. | ||
**Yarragadee** | **Yarragadee** |