Line 35: Line 35:
   * 02:50 UT: error ib -10 fixed, errors with dbbc communication - cycling power. (Bryn)   * 02:50 UT: error ib -10 fixed, errors with dbbc communication - cycling power. (Bryn)
   * 03:04 UT: Reconfigured DBBC and synced time with fmset. (Bryn)   * 03:04 UT: Reconfigured DBBC and synced time with fmset. (Bryn)
-  * 03:10 UT: LO was not locked, restarted Rxmon. (Bryn)+  * 03:10 UT: LO was not locked, restarted Rxmon. ​System temperatures are way off (values between -180000 and 90000) (Bryn) 
 +  * 03:25 UT: Halted schedule again - trying to sort out system temperatures. (Bryn) 
 +  * 04:15 UT: Schedule resumed - IF attenuation levels were not being automatically set due to a communication error (causing the errant tsys values) - First scan will be 139-0417a. **Missed/​bad scans are 139-0247 through 139-0415** ​(Bryn)
   *    * 
  