handover:r1754 [2016/08/23 02:54]
Jamie McCallum
handover:r1754 [2016/08/23 03:17] (current)
Jamie McCallum
Line 8: Line 8:
    * 0244UT: Brief power outage - drives had to be restarted with antenna=open,​ antenna=operate (JMc). ​    * 0244UT: Brief power outage - drives had to be restarted with antenna=open,​ antenna=operate (JMc). ​
    * 0254UT: Scan 0251 terminated to restart FS - GPIB converter had to be power cycled via pdu2ke (JMc)    * 0254UT: Scan 0251 terminated to restart FS - GPIB converter had to be power cycled via pdu2ke (JMc)
 +   * 0256UT: Another power glitch. FS machine rebooted but reboot has caused a fsck (JMc).
 +   * 0322UT: Schedule resumed (JMc). No useful data between 0251-0322
  
  