Previous revision
handover:r1911 [2019/09/09 21:45]
Pradyumna Kiran Kummamuru
handover:r1911 [2019/09/10 10:19] (current)
Pradyumna Kiran Kummamuru
Line 9: Line 9:
    * 1700UT - Experiment started OK (Prad).    * 1700UT - Experiment started OK (Prad).
    * Unusually delayed response at the FS to commands entered from erc . Hence, just using the oprin window in the vnc viewer. The disk module graphic in the erc is not updating (Prad).    * Unusually delayed response at the FS to commands entered from erc . Hence, just using the oprin window in the vnc viewer. The disk module graphic in the erc is not updating (Prad).
-   * 1919UT - Antenna stuck. Tried '​source=disable',​ '​antenna=open',​ switching drives on and off and rebooting central in the HMI, but to no avail.  +   * 1919UT - Antenna stuck at scan# 252-1928b. Tried '​source=disable',​ '​antenna=open',​ switching drives on and off and rebooting central in the HMI. The schedule restarted at scan# 252-2154b after attempting the reboot multiple times. (Prad)
-   ​* ​ +   ​* ​2156UT - scan_check reports mk5 data format problem (letter E issue) for scan# 252-2154b. Will require a module swap if the issue persists (Prad). 
 +   * erc displaying wrong DOY and UT. 
 +   * 04:52 UT recorded data ahead of scheduled by 112 GB (warren) 
 +   * 09:47 UT Waiting at limit for several scans. Field system had forced antenna to limit and would not take new source commands. Restarted the field system and schedule at scan 253-1025a. Scans 253-0953 through 253-1019 not on target (Ross) 
  
 {{tag>}} {{tag>}}