handover:r4726 [2016/02/12 00:29]
Jim Lovell
handover:r4726 [2016/02/12 16:20] (current)
Jim Lovell
Line 5: Line 5:
 Module: HOB+0119, start pos: 4893 GB Module: HOB+0119, start pos: 4893 GB
  
-(From previous handover notesNo other module ​to record ontoR1726 first experiment ​on here.)+  * 18:33 UT - Experiment started 6 min late due to slow setup (Missed scans 042-1830b to 042-1836). (Bryn) 
 +  * 00:37 UT - the wind sensor in Ke is broken. Brett disconnected it last week, now it is sending a '​stow-command'​ in the System Monitor. This should be ignored and does not actually cause the antenna ​to stow. (Lucia) 
 +  * 14:10 UT Accidently cycled Hb DBBC instead of Ke.. scans affected: 043-1408043-1411, 043-1414, 043-1422, 043-1426a, 043-1433, 043-1434b, 043-1440b 
 +  * 14:30 UT DBBC timeout. Rebooted DBBC and ran fmset 
 +  * 14:55 UT restarted PCFS due to log monitor not displaying '​recording'​ 
 +  * 15:23 UT ALARM: Delay through DBBC has changed. Monitor for stability and reset DBBC if it drifts. Rebooted DBBC and reran fmset again 
 +  * 15:44 UT ALARM: Delay through DBBC has changed. &  WARNING: Mark5 reports sync error. Recording seems to be OK, possibly due to break in schedule? 
 +  * 15:52 UT ALARM: Large difference between formatter and maser delays. & Still Mark5 sync error. Ran fmset to resync, syncerror_gt_3 is now syncerr_eq_0 
 +  * Restarted ​on scan 043-1608Appears to be OK now. (missed 043-1448b, 043-1451, 043-1453a, 043-1456a, 043-1501, 043-1505, 043-1507, 043-1511b, 043-1517, 043-1523, 043-1531, 043-1534, 043-1538b, 043-1540, 043-1544b, 043-1551, 043-1555, 043-1604 due to halting the schedule to restart the dbbc, and due to mark5 sync errors)
  
-  * 18:33 UT - Experiment started (Missed scans 042-1830b to 042-1836). (Bryn) 
  
 **Katherine 12m** **Katherine 12m**
Line 13: Line 20:
 Module: BKG+0135, start pos: 0 GB Module: BKG+0135, start pos: 0 GB
  
-  * 18:33 UT - Experiment started (Missed scans 042-1830b to 042-1836). (Bryn) +  * 18:33 UT - Experiment started ​6 min late due to slow setup (Missed scans 042-1830b to 042-1836). (Bryn) 
 +  * 14:08:46 ALARM: Delay through DBBC has changed. Scan affected is 043-1408 (Jonathan) 
 +  * Again at 14:15. Rebooting DBBC 
 +  * 14:20 reconfigured DBBC: scans affected: 043-1408, 043-1411, 043-1414, 043-1422, 043-1426a, 043-1433, 043-1434b, 043-1440b
/home/www/auscope/opswiki/data/attic/handover/r4726.1455236948.txt.gz · Last modified: 2016/02/12 00:29 by Jim Lovell