Line 32: Line 32:
 If you need to restart a transfer, or re-transfer a subset of files, then start the tsunami server with something like ''​tsunamid --port=52100 r1599_hb_234-15* r1599_hb_234-16*''​. This is necessary as tsunami defaults to overwriting any existing files and it starts from the top of the list. If you need to restart a transfer, or re-transfer a subset of files, then start the tsunami server with something like ''​tsunamid --port=52100 r1599_hb_234-15* r1599_hb_234-16*''​. This is necessary as tsunami defaults to overwriting any existing files and it starts from the top of the list.
  
 +=== Updating the transfer page ===
 +
 +When you start a transfer (or when one completes) please update the [[http://​www3.mpifr-bonn.mpg.de/​cgi-bin/​showtransfers.cgi|Bonn e-transfer website]]. This is done by copying an empty file with a properly formatted name to Bonn. There is a script on cornucopia, vortex and jupiter called ncBonn.sh which will assist you in this, but the full instructions are included below.
 +
 +To send a start message, use the following commands: ​
 +
 +%%touch 20130902033000_aust12hb_Hb209_Curtin_250m_52100_cuppa24_start%%\\
 +%%ncftpput ftp.mpifr-bonn.mpg.de /​incoming/​geodesy/​transfers 20130902033000_aust12hb_Hb209_Curtin_250m_52100_cuppa24_start%%
 +
 +The underscore-separated items are respectively a timestamp in UT, the experiment being transferred,​ the tsunami server (Hb for Hobart and 177 for the last number in the IP address), the destination,​ the transfer rate, the transfer port, the destination raid and lastly the word start. ​
 +
 +When a transfer completes, send a stop message with 
 +
 +%%touch 20130902033000_Hb209_stop%%\\
 +%%ncftpput ftp.mpifr-bonn.mpg.de /​incoming/​geodesy/​transfers 20130902033000_Hb209_stop%%
 +
 +You must use the same serial number (timestamp) as in the start message.
  