 +<​code>​
 + rfpic - AuScope RF PIC Control command
  
 +Syntax: ​   rfpic=xband,​sband,​fan
 +
 +Response: ​ rfpic/​0,​xband,​sband,​fan
 +           ​rfpic/​1,​calp15v,​calp12v,​calp5v,​calp20v,​pcal12v,​volts5
 +           ​rfpic/​2,​SR15v,​SL15v,​SL12v,​SR12v,​X15v,​X12v,​volts28
 +           ​rfpic/​3,​calTempC,​focusTempC,​RFboxTempC,​fspeed,​pedRH,​pedTempC
 +           ​rpfic/​4,​wavegRH,​wavegTempC,​wavegPresInput,​wavegPresInternal
 +    ​rfpic/​5,​spare1,​spare2,​spare4,​spare4
 +           ​rfpic/​6,​genReady,​spare1,​genStatus,​lolock
 +
 +
 +Settable parameters:
 +
 +xband      X-band switch state: cross or direct. Default is no change.
 +sband      S-band switch state: cross or direct. Default is no change.
 +fan        Fan override state toggle, only allowed value is "​toggle"​.
 +           ​Default is no change. Monitor response, is "​auto"​ or "​override"​
 +
 +Monitor-only parameters:
 +calp15v     CAL plate +15 V supply (volts)
 +calp12v  ​   CAL plate +12 V supply (volts)
 +calp5v  ​   CAL plate +5 V supply (volts)
 +calp20v  ​   CAL plate +20 V supply (volts)
 +pcal12v  ​   Phase CAL +12V Supply (volts)
 +volts5 ​             PIC +5V Supply (volts)
 +
 +SR15v  ​   S-band RHC +15V Supply (volts)
 +SL15v  ​   S-band LHC +15V Supply (volts)
 +SL12v  ​   S-band LHC +12V Supply (volts)
 +SR12v  ​   S-band RHC +12V Supply (volts)
 +X15v  ​   X-band +15V Supply (volts)
 +X12v  ​   X-band +12V Supply (volts)
 +volts28  ​   +28V supply (volts)
 +
 +calTempC  ​   CAL Plate Temperature (Celsius)
 +focusTempC  ​   Focus temperature (Celsius)
 +RFboxTempC  ​   RF Box temperature (Celsius)
 +fspeed  ​   Fan Speed (RPM)
 +pedRH  ​   Pedestal Relative Humidity (%)
 +pedTempC  ​   Pedestal temperature (Celsius)
 +
 +wavegRH  ​   Waveguide Air supply Relative Humidity (%)
 +wavegTempC  ​   Waveguide Air supply temperature (Celsius)
 +wavegPresInput  ​   Waveguide Air Pressure input (uncalibrated)
 +wavegPresInternal ​  ​Waveguide Air Pressure internal (uncalibrated)
 +
 +spare1  ​   Spare
 +spare2  ​   Spare
 +spare3  ​   Spare
 +spare4  ​   Spare
 +
 +genReady  ​   Generator Readiness: "​auto"​ or "​manual"​
 +genStatus  ​   Generator Status: "​off"​ or "​on"​
 +lolock  ​   LO Lock indicator: "​unlocked"​ or "​locked"​
 +
 +Comments:
 +The command provides monitor and control of the RF PIC.
 +
 +Command parameters are in three separate sets: (1) xband, (2) sband,
 +and (3) fan.  Each set can be commanded without affecting the others,
 +or in combination with others, by leaving parameters that are not to
 +be updated null (empty). Trailing null parameters may be omitted,
 +</​code>​