Line 11: Line 11:
   * [[operations:​documentation:​lba_starting_and_monitoring|Starting and monitoring observations]]   * [[operations:​documentation:​lba_starting_and_monitoring|Starting and monitoring observations]]
  
-Starting from scratch (using VNC sessions timeke:0 dbbcke:0 pcfske:1) 
-  * Check Displays on timeke (antenna, maser, anemometer, Clock) 
-  * Check DBBC server is running in dbbcke 
-  * On pcfske: 
-    * ssh to mk5ke and check mk5 software is running 
-    * Start FS 
-    * run fmset, check clocks are OK (looking for NO sycerr_gt_3 for Mark5B, all 3 times synchronised). If a problem, use option '​s'​. ESC when finished ​ 
-      * in the FS load the first non-fringe-finding experiment : 
-        * proc=v252aike 
-        * setup01 
-      * Now do a test recording check spectra and bit stats 
-        * disk_record=on 
-        * disk_record=off 
-        * scan_check 
-        * postob 
-      * Start the schedule 
-        * schedule=vc189ke 
-  *  