AUA073
Hobart 26m
Disk VSN: MAT+004 | Data volume at beginning: 2102.4 GB
- 1800UT Experiment started okay (Patrick).
- 2255-0010 Windstow (JMc)
- Tsys values seem high, IF power apparently low. Might be an issue with amplifier gains causing loss of sensitivity. Will investigate tomorrow (JMc)
Hobart 12m
Disk VSN: flexbuffhb
- 1800UT Experiment started okay (Patrick).
- ~2300-2328 Windstow. (JMc)
- 0234 PCAL on. (JMc)
- 2200 UT (after experiment) - Noted that sampler 3 is reporting poor statistics. Check the dbbc log!
- ~1530 - Sampler 3 (X-band.X-pol) lost lock.
Katherine 12m
Disk VSN: flexbuffke
- 1800UT Experiment started okay (Patrick).
- 2300 UT - Samplers show poor statistics. Stopping to reconfigure (JMc)
- 2312UT - Back on schedule (JMc)
- NB - Sampler 2 statistics are “Bad”, but still getting good performance. Carrying on for now (JMc)
- 0234 PCAL on. (JMc)
- Sampler 3 intermittently reporting as “Bad”. Still seems ok, so not trying a reconfigure. Issue seems to be the correlation statistics near to 170E6, Will need to address this if values go below 165E6 (JMc).
- Samplers lost lock ~1320 (JMc)
Yarragadee 12m
Disk VSN: MAT-0008 | Data volume at beginning: 0.06 GB
- 1800UT Experiment started okay (Patrick).
- 0315 - XLRappend Errors with mk5yg (JMc)
- 0350 - Back on schedule with HAY-0055 (JMc).