Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
operations:agenda2022_06_23 [2022/06/23 12:36]
Jayender Kumar
operations:agenda2022_06_23 [2022/06/23 13:14] (current)
Jayender Kumar
Line 3: Line 3:
 **Next meeting chair: ** Eloise **Next meeting chair: ** Eloise
  
-**Attended: ** +**Attended: ** Simin, japer, Eloise, Ahmad, Warren
  
-**Apologies: ** +**Apologies: ** Earl, David
  
 **General Issues:** **General Issues:**
      
-Jamie has updated the slogit script to deal with the new BKG server requirements so note new syntax for slogit and flogit. Check the wiki.  
  
 **Handover issues: ** **Handover issues: **
Line 17: Line 16:
 r11056 r11056
 Antenna stuck multiple times. 'antenna=open' & 'antenna=operate' solved it temporarily. reset timeyg solved it. (Ahmad) Antenna stuck multiple times. 'antenna=open' & 'antenna=operate' solved it temporarily. reset timeyg solved it. (Ahmad)
 +- Try switching drivers off/on on timeyg machine. if that doesn't work then restart timeyg
  
 ohg138 ohg138
  
 For some reason “mk5=vsn?” query won't display the disk name (it's just blank) but it “mk5=rtime?” says there is an empty disk ready to go (verified with webcam) and recording seems ok (Jasper) For some reason “mk5=vsn?” query won't display the disk name (it's just blank) but it “mk5=rtime?” says there is an empty disk ready to go (verified with webcam) and recording seems ok (Jasper)
 +- sometimes that happens when you put in new disk. Try labelling the vsn using mk5=disk_protect=0ff and mk5=vsn='module name' commands
  
 R41054 R41054
Line 30: Line 31:
 DBBC internal delays jumped, clkoff ok. Autocorrelation spectra are wrong (fixed values?) for all channels except the last two. Schedule halted at 0147, DBBC software restarted. (JMc) DBBC internal delays jumped, clkoff ok. Autocorrelation spectra are wrong (fixed values?) for all channels except the last two. Schedule halted at 0147, DBBC software restarted. (JMc)
  
-Hobart 12m +- keep an eye on  Autocorrelation spectras. spectras going bad generally means that there ddbc board jumped. also see the jump in delay live plots. restrarting or reconfiguring dbbc will be the right thing to do in that case
- +
-Power outage (Lim)+