Line 22: Line 22:
   * Check the status of the DBBC/mark5 with ''midob'' - this will call many monitoring commands. Some things to look for in the output are listed below   * Check the status of the DBBC/mark5 with ''midob'' - this will call many monitoring commands. Some things to look for in the output are listed below
       * ''iread'' - Check that the IF power levels match the targets **NB** - Hobart often has problems with A/B due to RFI so variations of ~20% are not unusual       * ''iread'' - Check that the IF power levels match the targets **NB** - Hobart often has problems with A/B due to RFI so variations of ~20% are not unusual
-      * ''bread'' - Confirm that all channels are in AGC mode and that the power levels are ~15000 for bbc017-32 and between ~8000 and 30000 for bbc001-bbc012 (S-band RFI)+      * ''bread'' - Confirm that all channels are in AGC mode and that the power levels are ~15000 for bbc017-32 @Ke ]/[ bbc033-048 @ Hb ] and between ~8000 and 30000 for bbc001-bbc012 (S-band RFI)
       * ''wth'' should return temperature/pressure/humidity values at Hb. Ke data still not available unfortunately.       * ''wth'' should return temperature/pressure/humidity values at Hb. Ke data still not available unfortunately.
       * ''clkoff'' and ''maserdelay'' should have a stable difference (~-0.11 microsec at Katherine, ~0.6 microsec at Hb).        * ''clkoff'' and ''maserdelay'' should have a stable difference (~-0.11 microsec at Katherine, ~0.6 microsec at Hb). 
Line 32: Line 32:
       * Log in to terminals on each of pcfs-2hb and pcfs-2ke and run''~/AuscopeVLBI/dbbc3_multicast.py'' The summarised output gives a green OK or red NO when things are out of range. Hobart12 often has issues with the power readings for A/B, due to RFI.  (Not available on pcfshb or pcfske where we are running the fs)       * Log in to terminals on each of pcfs-2hb and pcfs-2ke and run''~/AuscopeVLBI/dbbc3_multicast.py'' The summarised output gives a green OK or red NO when things are out of range. Hobart12 often has issues with the power readings for A/B, due to RFI.  (Not available on pcfshb or pcfske where we are running the fs)
       * Ke requires IF's ABCD to be good (ignore EF, not used)       * Ke requires IF's ABCD to be good (ignore EF, not used)
-      * Hb requires IF's ABEF to be good (ignore CD, not used)+      * Hb requires IF's ABEF to be good (ignore CDGH, not used)
  